Command device
ES 14
Thermoplastic enclosure
Double insulated X
Slow action
Mounting hole diameter 22.5 mm
Mounting details to EN 50047
With pre-wired cable
ES 14 RSSA 14-1m
ES 14 RS SW 1Ö/1S-1m
ES 14 RSSA 12-1m
ES 14 RSSA 13-1m
ES 14 RSSA 15-1m
ES 14 RSSA 17-1m
ES 14 RSSA 18-1m
ES 14 RSSA 23-1m
ES 14 RSSA 24-1m
ES 14 RSSA 27-1m
ES 14 RSTA 0 ← I-1m
ES 14 RSTB I → 0 ← II-1m
Technical data
General technical data
Applied standards
EN 60947-5-1, EN ISO 13849-1, emergency stop devices: EN 60947-5-5 and EN ISO 13850
Enclosure
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Degree of protection
IP65/IP67 (IEC/EN 60529)
B10d (10 % load)
60 000
TM
max. 20 years
Contact material
silver
Switching system
slow action, positive break NC contacts A
Switching elements
1 NC/1 NO contact or 2 NC contacts, type Zb
Connection
pre-wired cable H05VV-F
Cable cross-section
4 x 0.75 mm²
Cable length
1 m
Rated impulse withstand voltage Uimp
4 kV
Rated insulation voltage Ui
250 V
Conventional thermal current Ithe
6 A
Rated operating current/voltage Ie/Ue
6 A/250 VAC; 0.25 A/230 VDC
Utilisation category
AC-15; DC-13
Short-circuit protection
6 A gG/gN fuse
Ambient temperature
–20 °C … +75 °C
Mechanical life
> 30 000 operations
Operation cycles
max. 1800/h
Contact opening
max. 2 x 4 mm
Approvals
]
Downloads
Variants / Options
The following variants / options are available on request:
- Contact overlapping
- Other cable lengths
- Gold-plated contacts
- Plug-in connector M12 x 1, 4-pole
- Cable entry on side