Product features
With enable function
Metal enclosure
High level of stability
Low pedal height
Wiring compartment
NO contacts 33-34 and 43-44 are converted into positive break NC contact A by internal baffle after pressure point,
Safety contacts: 33-34 and 43-44 APlus 1 NC/1 NO contact, NC contact: direct opening action as signal contact after pressure point
Technical data
General technical data
Applied standards
EN 60947-5-8, EN ISO 13849-1, GS-ET-22
Enclosure
aluminium die-cast, powder-coated
Cover
aluminium die-cast, powder-coated
Pedal
thermoplastic, glass-fibre reinforced, shockproof, self-extinguishing UL 94 V-0
Degree of protection
IP65 (IEC/EN 60529)
B10d (10 % load)
2 million
TM
max. 20 years
Connection
screw connection terminals
Cable cross-section
min. 0.5 mm², max. 2.5 mm² (rigid or flexible with conductor ferrules)
Cable entry
1 x M25 x 1.5
Contact material
silver
Degree of pollution
3
Safety class
I
Overvoltage category
III
Switching system
slow action, positive break NC contacts A
Switching elements
2 NO contacts + 1 NC/1 NO contact
Switch insert
1 x EM 232 IK 2S + 1 x ES 60 1Ö/1S per pedal
Utilisation category
AC-15
Rated impulse withstand voltage Uimp
6 kV
Rated insulation voltage Ui
400 V
Conditional short-circuit current
1100 A
Conventional thermal current Ithe
3 A
Rated operating current/voltage Ie/Ue
3 A/400 VAC
Short-circuit protection
4 A gG/gN fuse
Ambient temperature
–25 °C … +80 °C
Mechanical life
> 1 million operations
Actuating force
min. 18 N, max. 170 N
Weight
1600 g